Adjustment And Acceptance Of Operation Lights
Dec 11, 2017

Debugging usually includes the following:

(1) Mechanical installation check: see if there are any mechanical installation flaws, there are no screws or screws are not tight. Card Spring has a good card, the various decorative cover plate has been covered.

(2) Circuit check: first check whether the system has short circuit or open circuit. If all is normal, can carry on the electricity test, at this time should check the external power supply of the lamp is stable. Whether the transformer output voltage is too high or too low.

(3) Balance arm adjustment: To see whether the balance arm and the lamp holder match, whether it is necessary to adjust the force of the balance arm, whether it is necessary to adjust the angle of the balance arm and needs can be adjusted by means of adjusting the lamp arm. Usually adjust the lamp arm of the screws at the two ends of the lamp arm, but different manufacturers slightly different, can be carefully observed.

(4) The flexibility of the joint adjustment: mainly to regulate the joints of the damping screws, the standard regulation of the tightness of the damping is in any position to promote or rotate the joint force close to 20N or 5Nm.

(5) The adjustment and Songqi of the joint limit switch: In order to facilitate the installation and transportation of the light, most of the light products in its key parts such as joints are set to lock dead switches or limit switches. can now be opened.

(6) Check the irradiation distance and depth: most of the light exposure distance in the 70-140cm or 60-130cm. The lamp is the best in the distance.

(7) Check illuminance and color temperature: illuminance and color temperature are actually an approximate concept. is to describe the intensity of the illumination. Usually, we think that the ideal light is the approximate sunlight and the sun. That is around 4400-4600k.

The above-mentioned adjustment, inspection of qualified operation lights can be put into use.


Company Name:Vega Medical Equipment(Shanghai)

Tel:+86-021-67105200

Website:http://www.vega-medi.com

Mobile:+86-15900473404

Contact: Laura  duan

E-mail:sales@vega-medical.com.cn

Company Add:Room 512, Lvdifangzhou Building, No. 258, North Of Yunhe Road, Fengxian District, Shanghai, China (Mainland)

Factory Add:No.618,Jianyun Road,Meilin Village,Zhoupu Town,Pudong New Area,Shanghai,China  

No.688,Guangjian Road,Yangwang Industrial Zone,Fengxian District,Shanghai,China


  • Newsletter
  • Categories
  • Contact Us
    Vega Medical Equipment(Shanghai)
    Add: No.618, Jianyun Road, Zhoupu Industrial Park, Pudong New Area, Shanghai, China
    Tel: +86-021-67105200
    Mobile: +86-15900473404
    E-mail: sales@vega-medical.com.cn
  • QR Code
  • Copyright © Vega Medical Equipment (Shanghai) All Rights Reserved.